subconscious.ai
← All studies

Research study · 2020

GrahamClarke2020

Patient Preferences for Biologic and Biosimilar Osteoporosis Treatments in Colombia. Paper ↗

Spearman ρ ↑
0.805
Normalized RMSE ↓
Not measured
Same direction
86%
Same winner
72%

Saved run · 2026-11-03 · 7 paired effects · Inspect run ↗

Human vs synthetic effects

After scale calibration · logit coefficient

-2.22-2.220.000.001.851.85Type of osteoporosis medicine: Original biologic medicine. Human 1.570; calibrated synthetic 0.168.Length of the needle: 4 mm. Human 1.266; calibrated synthetic 0.751.Length of the needle: 6 mm. Human 0.868; calibrated synthetic 0.747.Angle of injection: At a 90-degree angle. Human -0.204; calibrated synthetic 0.315.How to measure the medicine dose for each injection: You set the correct dose yourself. Human -1.002; calibrated synthetic -1.936.How long the medicine can be left out of the refrigerator when traveling: Never (must be kept in a cooler when traveling). Human -0.598; calibrated synthetic -1.589.How long the medicine can be left out of the refrigerator when traveling: Can be left out of the refrigerator for up to 24 hours (1 day). Human -0.298; calibrated synthetic -0.299.Human effectCalibrated synthetic effect

Dashed line: equal effects. × Opposite direction. Scale fitted with k = 4.2793; raw size agreement: not comparable.

What matters most

Attribute importance · share of total effect range

● Human ◆ Synthetic

Type of osteoporosis medicine
Length of the needle
How to measure the medicine dose for each injection
How long the medicine can be left out of the refrigerator when traveling
Angle of injection

LLM results

3 configured models · latest scored run per model and arm where available · settings and answer keys differ; not a controlled ranking.

Direct prompt

Configured modelSpearman ρ ↑−1 to 1Normalized RMSE ↓0 to 1.00
SpearmanSpearman: 0.865
Normalized RMSE: Not measured
SpearmanSpearman: 0.617
Normalized RMSE: Not measured

Simulated respondents

Configured modelSpearman ρ ↑−1 to 1Normalized RMSE ↓0 to 1.00
SpearmanSpearman: 0.805
Normalized RMSE: Not measured
Exact metrics, all 3 saved runs and settings
Configured modelSpearman ρ ↑Normalized RMSE ↓Scaled RMSE ↓Answer key / dateArm / settings
claude-opus-5-5 ↗0.865Not measured0.358logit · k 1.2598hb-def-GrahamClarke2020:v02026-11-04 · 12 scored levelsDirect prompt

Convention: inclusive
Estimator: Direct utility estimate

prompt version
direct-v2
samples
3
jev-1.13.0 ↗0.617Not measured0.533logit · k 0.1612hb-def-GrahamClarke2020:v02026-11-04 · 12 scored levelsDirect prompt

Convention: inclusive
Estimator: Direct utility estimate

prompt version
direct-v2
samples
3
typesafe:jev-1.13.0 ↗Experiment · Trial0.805Not measured0.526logit · k 2.6854hb-def-GrahamClarke2020:v02026-11-03 · 12 scored levelsSimulated respondents

Convention: inclusive
Estimator: ols

response mode
fast
design seed
42
population seed
100
llm temperature
0
How to read these metrics

Spearman ρ measures agreement in level-effect ranking (−1 to 1; higher is better). Normalized RMSE divides unscaled RMSE by the standard deviation of human effects (unit-free; lower is better). Scaled RMSE fits a scale factor k and retains each run’s human-effect units; compare it only within the same reference and units. Missing values remain unmeasured.

Model names come from recorded configuration, unless a routing discrepancy is noted. A configured name alone does not verify the provider that answered.

When choices agree

Same winner by human preference margin · 39,428 pairs

smallest fifth
second fifth
middle fifth
fourth fifth
largest fifth

Five equal-count groups, from closest choices to clearest preferences.

Effects on a common scale

● Human ◆ Calibrated synthetic · Human 95% intervals where saved

-2.1302.13
Type of osteoporosis medicine: Original biologic medicineType of osteoporosis medicine: Original biologic medicine
Length of the needle: 4 mmLength of the needle: 4 mm
Length of the needle: 6 mmLength of the needle: 6 mm
Angle of injection: At a 90-degree angleAngle of injection: At a 90-degree angle
How to measure the medicine dose for each injection: You set the correct dose yourselfHow to measure the medicine dose for each injection: You set the correct dose yourself
How long the medicine can be left out of the refrigerator when traveling: Never (must be kept in a cooler when traveling)How long the medicine can be left out of the refrigerator when traveling: Never (must be kept in a cooler when traveling)
How long the medicine can be left out of the refrigerator when traveling: Can be left out of the refrigerator for up to 24 hours (1 day)How long the medicine can be left out of the refrigerator when traveling: Can be left out of the refrigerator for up to 24 hours (1 day)
Exact effects and uncertainty (12 levels)
Human and calibrated synthetic effects
Attribute / levelHumanHuman 95% half-widthCalibrated synthetic
Type of osteoporosis medicine: Original biologic medicine1.570Not measured0.168
Type of osteoporosis medicine: Biosimilar medicine (reference)0.000Not measured0.000
Length of the needle: 4 mm1.266Not measured0.751
Length of the needle: 6 mm0.868Not measured0.747
Length of the needle: 12 mm (reference)0.000Not measured0.000
Angle of injection: At a 90-degree angle-0.204Not measured0.315
Angle of injection: At a 45-degree angle (reference)0.000Not measured0.000
How to measure the medicine dose for each injection: You set the correct dose yourself-1.002Not measured-1.936
How to measure the medicine dose for each injection: Pen sets the correct dose automatically (reference)0.000Not measured0.000
How long the medicine can be left out of the refrigerator when traveling: Never (must be kept in a cooler when traveling)-0.598Not measured-1.589
How long the medicine can be left out of the refrigerator when traveling: Can be left out of the refrigerator for up to 24 hours (1 day)-0.298Not measured-0.299
How long the medicine can be left out of the refrigerator when traveling: Can be left out of the refrigerator for up to 36 hours (1½ days) (reference)0.000Not measured0.000
Interpretation and limits

Right direction on 6 of 7 effects, close ranking (ρ = 0.80); sizes not comparable (the paper reports logit coefficients).

Use it to screen which attributes move choice; sizes need the paper's respondent data, and confirm the reversed effect with people.

direction
mixed
rank
holds
size
not comparable

Spearman 95% interval: 0.396 to 0.947.

Supported uses

  • Ranking attributes and levels by how strongly they move choice.

Limits

  • Decisions that hinge on the attributes whose direction flipped (listed below).
  • Effect sizes in the paper's units; only direction, rank and shape are compared.

Calibration multiplies synthetic effects by k; agreement after scaling does not establish agreement in raw sizes. Missing metrics remain unmeasured.

About the study

01 / Human finding

What the study found

A reviewed summary is not available in this registry. Consult the published paper for the original finding.

Answer-key review: Not reviewed

02 / Experiment design

Who chose, and what varied

Country
Not recorded
Human respondents
Not recorded
Attributes
Not recorded
Task
Not recorded
Registry and historical replication summaries

03 / Synthetic replication

Registry replication results

Current replication

Spearman rank correlation

Not measured

No run built from the current answer key is scored yet.

Paper-era reference

2023 CLM mean Spearman ρ

Not measured

Historical results use their original estimator and reference. They are not a matched comparison with the current run.

Sources and measurement provenance

Missing results mean unmeasured, not zero agreement.

  • missing parent paper url
  • missing canonical pdf
  • missing transcription
  • missing historic score
  • missing resolved wandb run

Registry revision: 61134e3c3304. Estimator: ols.

    Evidence snapshot · 2026-11-26